Call (800) 663-5523 for a Quote or Additional Information
Get convergence, performance and scalability in a compact, fully unified hybrid storage system that can grow with your organization. The Nexsan NST Hybrid Storage system simultaneously supports Fibre Channel, iSCSI, NFS, CIFS, SMB and FTP protocols within a single storage operating system leveraging DRAM and SSDs to create a caching tier called FASTier™. With FASTier, Nexsan NST Hybrid Storage System is able to support the most demanding block-level SAN and file-level NAS workloads within one system, effectively solving your SAN versus NAS debate.
The NST6000 unified storage system offers high performance controllers and an expanded front-end FASTier™ caching engine connected to efficient E-Series storage arrays of NL-SAS / Performance SAS drives or to compact NST224X storage enclosures of 2.5″ Performance SAS drives.
[restabs alignment=”osc-tabs-left” responsive=”false”]
[restab title=”Overview” active=”active”]
The Nexsan NST6000 along with NestOS 3.0 is highly scalable unified storage solution in a compact footprint that uses a caching technology called FASTier® to accelerate reads and writes I/O requests. FASTier intelligently and automatically moves data through solid-state and spinning disk to speed your virtual and cloud environments.
Built with the time-constrained IT administrator in mind, a revolutionary GUI streamlines setup and management to ease the pain of mid-sized organizations challenged by storage complexity.
Key Features Include:
[/restab]
[restab title=”Features”]
Unified
The Nexsan NST6000 unified hybrid storage appliance is ideal for organizations seeking significantly increased application performance and simplified storage administration.
The NST6000 is a unified storage system.The NST6000 supports block-level – Fibre Channel, iSCSI (SAN) and file-level – NFS, CIFS, SMB, FTP (NAS) protocols without sacrificing performance and eliminating the need for separate software stacks and block and file licenses.
The NST6000 conveniently manages all protocols, pools, shares and LUNs within a single system. E-Centre, NST6000’s single-pane management interface, provides a single view to manage all SAN and NAS storage.
Hybrid
NST6000 is a hybrid storage system. NestOS, NST6000’s operating system, integrates the use of solid-state caching and hard disk storage to enable organizations to meet the most demanding I/O performance requirements of both SAN and NAS workloads.
NestOS’s FASTier caching technology is smart. It includes fault tolerant DRAM for the highest possible write caching performance and enterprise-class SSDs to accelerate read I/O, allowing you to independently customize your performance and capacity points.
FASTier read/write cache devices can be customized at a storage pool level, enabling organizations to extend the use of FASTier to many applications in the data center.
Unified Hybrid
The combination of solid-state technology, Fibre Channel connectivity, and a highly scalable back-end storage infrastructure makes the NST6000 platform ideal for continuous data availability supporting mission-critical IT applications.
Features & Benefits
Complete host connectivity in a single system and software stack: Fibre Channel, iSCSI, NFS, CIFS, SMB and FTP. NST6000 provides fully unified storage with no need to administer discrete tasks, code bases and separate licenses.
Application-friendly: Flexible read/write I/O acceleration tier, customizable to the needs of the Pools, LUNs or Shares presented to Hosts. NST6000’s FASTier acceleration technology increases storage I/O performance, lowers latency and extends the life of SSDs.
Smart, practical use of solid-state technology: Fault-tolerant DRAM delivers the highest write caching performance possible and enterprise-class SSDs accelerate read I/O performance. NST6000’s hybrid storage solution optimizes the use of solid-state technology for maximum effectiveness.
High-performance continuous availability: Powerful active/active controllers linked together via a high-speed backplane provide up to 700,000 IOPs and non-disruptive failover. NST6000’s mirrored write cache with cache vaulting ensures the highest levels of performance and availability. Combined with active/active RAID controllers within the underlying E-Series storage, NST6000 provides high availability storage that can scale up to 5 petabytes.
Adaptable storage infrastructure: Use SSDs, Performance-SAS HDDs and NL-SAS HDDs to meet varying storage requirements. NST6000 is a unified hybrid storage platform that can be customized and deployed for performance-oriented workloads, capacity-oriented workloads, or deploy both performance and capacity tiers within the same system. With the non-disruptive addition of FASTier or new disk enclosures, performance and capacity can be independently scaled.
Intuitive single-pane management: Interface and set-up assistants designed for the IT generalist. For advanced users the management software offers a command line interface for scripting. NST6000’s E-Centre GUI provides a single view to manage file and block traffic while leveraging various types of storage media.
[/restab]
[restab title=”Specifications”]
Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise
NST6530 | |
---|---|
NST6000 System Form Factor NST6000 Controllers NST6000 Vault Protection Modules |
6U 2 x 2U = 4U 2 x 1U = 2U |
NST6000 System CPU Type | Cores |
Xeon | 24 Cores 12 per Controller |
NST6000 System Memory (DRAM) Basic| Premium |
192 GB | 384 GB 96 GB | 192 GB per Controller |
FASTier Fault Tolerant Write Cache Capacity |
32 GB 64 GB Mirrored Capacity in System |
FASTier Read Cache Capacity Standard | Maximum |
4.4 TB | 9.2 TB |
Maximum FASTier Read Cache Devices |
Up to 46 Read Cache Devices |
FASTier Read Cache Types |
200, 400, 800GB eMLC | 100, 200GB SLC |
RAID Levels | RAID 5, RAID 6, RAID 10 |
Data listed in the table refers to a single 2U NST6000 Controller unless indicated otherwise
NST6530 | ||
---|---|---|
NST6000 Host Connectivity | ||
1GbE I/O Embedded STANDARD CONFIGURATION |
4 – port 1GbE 1 is management. 1 is reserved. |
|
10 GbE I/O PCIe Card STANDARD CONFIGURATION |
(1) dual-port 10GbE | |
PCIe Slots for Additional Host Connectivity |
2 | |
1GbE PCIe Cards OPTIONAL |
dual-port or quad-port 1GbE | |
10GbE PCIe Cards OPTIONAL |
dual-port 10GbE | |
8 Gb/s FC I/O PCIe Cards OPTIONAL |
dual-port or quad-port 8Gb | |
1GbE I/O Ports | 2 to 10 | |
10GbE I/O Ports | 2 to 6 | |
8 Gb/s FC I/O Ports | 0 to 8 | |
NST6000 SAS Storage Connectivity: Nexsan E-Series V Arrays | ||
6 Gb/s SAS STANDARD CONFIGURATION |
# of SAS Ports | 6 ports. 4 lanes (links) per port. Total SAS Bandwidth = 144 Gb/s. |
(1) dual-port (1) quad-port |
||
PCIe Card Type | ||
Nexsan E-Series V Storage # of RAID Arrays | Expansion Units |
3 E-Series V Arrays 6 Expansion Units 9 Total E-Series |
|
6 Gb/s SAS Switch OPTIONAL |
16 Mini-SAS wide ports 4 lanes (links) per port |
|
NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure | ||
6 Gb/s SAS STANDARD CONFIGURATION |
# of SAS Ports | 6 ports. 4 lanes (links) per port. Total SAS Bandwidth = 144 Gb/s. |
PCIe Card Type | ||
Nexsan NST224X Number of Enclosures |
||
(1) dual-port (1) quad-port |
||
Up to 9. | ||
6 Gb/s SAS Switch OPTIONAL |
16 Mini-SAS wide ports4 SAS lanes per port |
Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise. Additional capacities are available for the NL-SAS HDDs and Performance- SAS HDDs listed below.
NST6530 | |||
---|---|---|---|
NST6000 SAS Storage Connectivity: Nexsan E-Series V Array | |||
Nexsan E-Series V RAID Array Number of Head Units |
STANDARD CONFIG | WITH SAS SWITCH | |
3 E-Series Arrays | 7 E-Series Arrays | ||
6 Expansion Units | 14 Expansion Units | ||
9 Total E-Series | 21 Total E-Series | ||
E-Series V Arrays Types Available |
E18: 18 3.5” drives in 2U | ||
E48: 48 3.5” drives in 4U | |||
E60: 60 3.5” drives in 4U | |||
E-Series V Expansion Units Types Available |
E18X: 18 3.5” drives in 2U | ||
E48X: 48 3.5” drives in 4U | |||
E60X: 60 3.5” drives in 4U | |||
Max 3.5″ NL-SAS HDD Capacity Based on use of E60 and E60X Number HDD | Capacity @ 4TB/HDD |
STANDARD CONFIG | WITH SAS SWITCH | |
540 NL-SAS Drives | 1260 NL-SAS Drives | ||
2,160 TB | 5,040 TB | ||
Max 3.5″ Performance-SAS HDD Capacity Based on use of E60 and E60X Number HDD | Capacity @ 600GB/HDD |
STANDARD CONFIG | WITH SAS SWITCH | |
540 SAS Drives | 1260 SAS Drives | ||
324 TB | 756 TB | ||
NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure | |||
HDD 2.5″ 10K Performance SAS HDDs | Number of NST224X Enclosures | Up to 9. 24 HDDs / Enclosure. | |
Max Performance – SAS HDD Capacity Number HDD | Capacity @ 1.2 TB/HDD |
216 Drives | 259.2TB | ||
eMLC SSDs | Number of NST224X Enclosures | Up to 9. 24 SSDs / Enclosure. | |
Max External SSD Capacity Number SDD | Capacity @ 800 GB/SDD |
216 Drives | 172.8TB |
Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise
NST6530 | |
---|---|
Client Support | Linux, OS X, Unix, WindowsESXi, Hyper-V, XenServer |
Storage Services | Fibre Channel, iSCSI, NFS, CIFS,SMB, FTP |
Maximum Single File Size | 16 TB |
Max NFS Shares | 512 |
Max CIFS Shares | 512 |
Max Snapshots Per Share | 2,048 |
Maximum LUN Size | 64 TB |
Max LUNs Per Target | 255 |
System Max LUNs | 255 – Fibre Channel 1,024 – iSCSI |
Max Snapshots per LUN | 2,048 |
Data listed in the table refers to single 2U NST6000 Controller unless indicated otherwise
NST6530 | |
---|---|
Operating Temperature | 10-35C, 50-95F |
Operating Humidity | 20-95% (non-condensing) |
U of Rack Space | 2U |
Height | 3.5in, 8.76cm |
Width | 17.2in, 43.8cm |
Depth | 27.87in, 70.78cm |
Weight | >40lbs, >18.1Kg |
# hot swappable power supplies | 2 |
Maximum Power/Controller Node | < 430 W |
Voltage, Frequency | Voltage (110): 90-132V; Frequency47-63 Hz Voltage (220): 180-246V; Frequency47-63 Hz |
Heat Dissipation | 1467 btu/hr |
Data listed in the table refers to a single NST6000 Vault Protection Module unless indicated otherwise
NST6000 Vault Protection Module | ||
---|---|---|
120 V | 230 V | |
Dimensions | ||
Dimensions (H x W x D, inches) | 1.7 (1U) x 17.2 x 21.8 | 1.7 (1U) x 17.2 x 21.8 |
Dimensions (H x W x D, mm) | 43.2 x 438 x 554 | 43.2 x 438 x 554 |
Weight (kg) | 20.0 | 19.36 |
Weight (lbs) | 44.1 | 42.7 |
Battery | ||
Battery Description | Sealed. Lead-acid. Maintenance free. | |
Battery Management | Battery life management and advanced warning for battery replacement | |
Electrical | ||
Input / Output Connections | Input: (1) NEMA 5-15P; Output: (5)NEMA 5-15R | Input: (1) C14; Output: (6) C13 |
Input / Output Nominal Voltage | 120V (adjustable to 100/120/125 V) | 230V (adjustable to 200/208/220/230/240 V) |
Input / Output Frequency | 50 / 60 Hz | 50 / 60 Hz |
On Utility Voltage Regulation | 102 – 132 V | 102 – 132 V |
On Battery Voltage Regulation | – 10% – + 6% of Nominal | – 10% – + 6% of Nominal |
Communications | ||
User Interface | LCD Graphical Display | |
LEDs | Load protected, on battery and fault | |
Communication Card Slots | One Slot | |
Other | ||
RoHS Compliance | Yes | |
Heat Dissipation (BTU) | Line: 113, Battery 714 | |
Audible Noise | < 45 dB at 1 meter | |
Operating Temperature | 0-40C, 32-104F | |
Performance – Safety – EMC | UL 1778, UL497A | |
Safety Markings | cULus, CE | |
EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B | |
Storage Temperature | -15 – 40C, 5-10F | |
Relative Humidity | 0-95% (non-condensing) |
[/restab]
[restab title=”Documentations”]
[/restab][/restabs]
NST6530 Storage Platforms | |
NST6530-DC storage systems all contain dual controllers comprised of two six-core Intel Xeon processors, 96GB RAM, six 24Gbit SAS ports for storage connectivity and two 10GigE ports for host connectivity per controller. Includes core operating system, Data Protection Package and E-Centre management platform software licenses. Supports up to 3 storage head units. | |
NST6530 Unified Storage | Part Number |
RJ-45 Host Connectivity | |
NST6530-DC Storage System, including 2 x 10GigE RJ-45 host connectivity ports and 6 x 24Gb SAS storage connectivity ports. Contains two six-core Intel Xeon processors and 96GB RAM per controller, with dual-redundant active-active controllers – 120V/NEMA 5-15 (NOT compatible with 220V main) | NST6530R-DC |
NST6530-DC Storage System, including 2 x 10GigE RJ-45 host connectivity ports and 6 x 24Gb SAS storage connectivity ports. Contains two six-core Intel Xeon processors and 96GB RAM per controller, with dual-redundant active-active controllers – 220V/C14 (NOT compatible with 120V main) | NST6530GR-DC |
SFP+ Host Connectivity | |
NST6530-DC Storage System, including 2 x 10GigE SFP+ host connectivity ports and 6 x 24Gb SAS storage connectivity ports. Contains two six-core Intel Xeon processors and 96GB RAM per controller, with dual-redundant active-active controllers – 120V/NEMA 5-15 (NOT compatible with 220V main) | NST6530X-DC |
NST6530-DC Storage System, including 2 x 10GigE SFP+ host connectivity ports and 6 x 24Gb SAS storage connectivity ports. Contains two six-core Intel Xeon processors and 96GB RAM per controller, with dual-redundant active-active controllers – 220V/C14 (NOT compatible with 120V main) | NST6530GX-DC |
Host Connectivity (Select Maximum Two) | Part Number |
Pair of 10GbE NIC with dual RJ-45 interfaces, includes license to use | NST-10GR-DPCP |
Pair of 10GbE NIC with dual SFP+ SR interfaces, includes license to use | NST-10GS-DPCP |
Pair of 1GigE, Dual-port NIC, RJ-45 interfaces, includes license to use | NST-1GR-DPCP |
Pair of 1GigE, Quad-port NIC, RJ-45 interfaces, includes license to use | NST-1GR-QPCP |
Pair of 8Gb Dual-Port, Fibre Channel Host Connectivity cards, includes license to use | NST6K-FC8-HDPCP |
Pair of 8Gb Quad-Port, Fibre Channel Host Connectivity cards, includes license to use | NST6K-FC8-HQPCP |
FASTier Performance Boost (Optional) – Use NST6000 FASTier TAB and select accordingly for NST6000 model | |
Performance Packs | |
NST6500 | Part Number |
Performance Pack for NST6500. Increases controller RAM from 96GB to 192GB. | NST6500-PP1 |
Storage Units | |
SAS-connect E-Series or NST224X | Part Number |
See NST Storage Units to configure storage – Must select dual controller versions | |
NST6000 Hardware & Software Support | Part Number |
**All components must be under the same support level** | |
Basic Support – Annual Advance Shipped by NBD, Self Install FRU, Pricing per System per Site | |
Basic Support, Annual – Tier 1 License (16TB) | OSB-NST6K-16T |
Basic Support, Annual – Tier 2 License (16TB – 64TB) | OSB-NST6K-64T |
Basic Support, Annual – Tier 3 License (64TB – 128TB) | OSB-NST6K-128T |
Basic Support, Annual – Tier 4 License (128TB – 256TB) | OSB-NST6K-256T |
Basic Support, Annual – Tier 5 License (256TB – 512TB) | OSB-NST6K-512T |
Basic Support, Annual – Tier 6 License (512TB – 1024TB) | OSB-NST6K-1P |
Basic Support, Annual – Tier 7 License (1024TB – 2048TB) | OSB-NST6K-2P |
Basic Support, Annual – Tier 8 License (2048TB – 4096TB) | OSB-NST6K-4P |
Basic Support, Annual – Tier 9 License (4096TB – 8192TB) | OSB-NST6K-8P |
Enterprise Support – On-Site NBD, Pricing per System per Site | |
Enterprise Support, Annual – Tier 1 License (16TB) | OSE-NST6K-16T |
Enterprise Support, Annual – Tier 2 License (16TB – 64TB) | OSE-NST6K-64T |
Enterprise Support, Annual – Tier 3 License (64TB – 128TB) | OSE-NST6K-128T |
Enterprise Support, Annual – Tier 4 License (128TB – 256TB) | OSE-NST6K-256T |
Enterprise Support, Annual – Tier 5 License (256TB – 512TB) | OSE-NST6K-512T |
Enterprise Support, Annual – Tier 6 License (512TB – 1024TB) | OSE-NST6K-1P |
Enterprise Support, Annual – Tier 7 License (1024TB – 2048TB) | OSE-NST6K-2P |
Enterprise Support, Annual – Tier 8 License (2048TB – 4096TB) | OSE-NST6K-4P |
Enterprise Support, Annual – Tier 9 License (4096TB – 8192TB) | OSE-NST6K-8P |
NST6000 Hardware & Software Support | |
**All components must be under the same support level** | |
Premium Support – 4-Hour Response, Select GEO, Pricing per System per Site | |
Premium Support, Annual – Tier 1 License (16TB)* | OSP-NST6K-16T |
Premium Support, Annual – Tier 2 License (16TB – 64TB)* | OSP-NST6K-64T |
Premium Support, Annual – Tier 3 License (64TB – 128TB)* | OSP-NST6K-128T |
Premium Support, Annual – Tier 4 License (128TB – 256TB)* | OSP-NST6K-256T |
Premium Support, Annual – Tier 5 License (256TB – 512TB)* | OSP-NST6K-512T |
Premium Support, Annual – Tier 6 License (512TB – 1024TB)* | OSP-NST6K-1P |
Premium Support, Annual – Tier 7 License (1024TB – 2048TB)* | OSP-NST6K-2P |
Premium Support, Annual – Tier 8 License (2048TB – 4096TB)* | OSP-NST6K-4P |
Premium Support, Annual – Tier 9 License (4096TB – 8192TB)* | OSP-NST6K-8P |
Concierge Support – 4-Hour Response, Managed Services, Select GEO, Pricing per System per Site | |
Concierge Support, Annual – Tier 1 License (16TB)* | OSC-NST6K-16T |
Concierge Support, Annual – Tier 2 License (16TB – 64TB)* | OSC-NST6K-64T |
Concierge Support, Annual – Tier 3 License (64TB – 128TB)* | OSC-NST6K-128T |
Concierge Support, Annual – Tier 4 License (128TB – 256TB)* | OSC-NST6K-256T |
Concierge Support, Annual – Tier 5 License (256TB – 512TB)* | OSC-NST6K-512T |
Concierge Support, Annual – Tier 6 License (512TB – 1024TB)* | OSC-NST6K-1P |
Concierge Support, Annual – Tier 7 License (1024TB – 2048TB)* | OSC-NST6K-2P |
Concierge Support, Annual – Tier 8 License (2048TB – 4096TB)* | OSC-NST6K-4P |
Concierge Support, Annual – Tier 9 License (4096TB – 8192TB)* | OSC-NST6K-8P |
On-Site Installation | |
On-Site installation (per site) based on 1 day includes Travel applies to CONUS and W. Europe all other locations call. | OSI-NST6K-STD |
On-Site installation (per site) – Complex, based on Statement of Work. | OSI-NST6K-PROF |
NST Storage Units | |
Storage Unit option for FC or SAS for all NST5300s and NST5500s and FC only for all NST6000MCs and SAS only for the NST6530. | |
Existing customers with Legacy E-Series see Legacy Expansion Units tab to order expansion units. | |
Fibre Channel-connected 6Gb/s E-Series Storage Units | Part Number |
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 (max 9 chassis with expansions), maximum 4 head units can be added to NST6330MC, maximum 6 for NST6530MC, and maximum 8 for NST6730MC. | |
E18V with 8.1TB capacity- 450GB SAS Disk / 15000 RPM | E18VHNJ8P1/450 |
E18V with 10.8TB capacity – 600GB SAS Disk / 15000 RPM | E18VHNJ10P8/600 |
E18V with 36TB capacity – 2TB Disks / 7200 RPM | E18VHNJ36N/2 |
E18V with 54TB capacity – 3TB Disks / 7200 RPM | E18VHNJ54N/3 |
E18V with 72TB capacity – 4TB Disks / 7200 RPM | E18VHNJ72N/4 |
E48VT with 21.6TB capacity – 450GB Disks / 15000 RPM | E48VTNJ21P6/450 |
E48VT with 28.8TB capacity – 600GB Disks / 15000 RPM | E48VTNJ28P8/600 |
E48VT with 43.2TB capacity – 900GB Disks / 10000 RPM | E48VTNJ43J2/900 |
E48VT with 96TB capacity – 2TB Disks / 7200 RPM | E48VTNJ96N/2 |
E48VT with 144TB capacity – 3TB Disks / 7200 RPM | E48VTNJ144N/3 |
E48VT with 192TB capacity – 4TB Disks / 7200 RPM | E48VTNJ192N/4 |
E60VT with 27TB capacity – 450GB Disks / 15000 RPM | E60VTNJ27P0/450 |
E60VT with 36TB capacity – 600GB Disks / 15000 RPM | E60VTNJ36P0/600 |
E60VT with 120TB capacity – 2TB Disks / 7200 RPM | E60VTNJ120N/2 |
E60VT with 180TB capacity – 3TB Disks / 7200 RPM | E60VTNJ180N/3 |
E60VT with 240TB capacity – 4TB Disks / 7200 RPM | E60VTNJ240N/4 |
NOTE: For each E60, E48 or E18 selected, please add four (4) LC-LC cables from below. (Does not apply to E60X, E48X or E18X expansion units.) | |
NOTE: Metro Cluster units use single mode fibre provided by the customer. | |
Cables | Part Number |
Fiber Optic LC-LC cable, 3 Meters | CBL-007-3.0M |
Fiber Optic LC-LC cable, 5 Meters | CBL-007-5.0M |
SAS-connected 6Gb/s E-Series Storage Units | |
Maximum 2 storage units can be added to NST5300, maximum 3 for NST5500 and NST6530 (non-MC). | Part Number |
E18V with 8.1TB capacity- 450GB SAS Disk / 15000 RPM | E18VHNS8P1/450 |
E18V with 10.8TB capacity – 600GB SAS Disk / 15000 RPM | E18VHNS10P8/600 |
E18V with 36TB capacity – 2TB Disks / 7200 RPM | E18VHNS36N/2 |
E18V with 54TB capacity – 3TB Disks / 7200 RPM | E18VHNS54N/3 |
E18V with 72TB capacity – 4TB Disks / 7200 RPM | E18VHNS72N/4 |
E48VT with 21.6TB capacity – 450GB SAS Disks / 15000 RPM | E48VTNS21P6/450 |
E48VT with 28.8TB capacity – 600GB SAS Disks / 15000 RPM | E48VTNS28P8/600 |
E48VT with 43.2TB capacity – 900GB Disks / 10000 RPM | E48VTNS43J2/900 |
SAS-connected 6Gb/s E-Series Storage Units | |
Maximum 2 storage units can be added to NST5300, maximum 3 for NST5500 and NST6530 (non-MC). | Part Number |
E48VT with 96TB capacity – 2TB Disks / 7200 RPM | E48VTNS96N/2 |
E48VT with 144TB capacity – 3TB Disks / 7200 RPM | E48VTNS144N/3 |
E48VT with 192TB capacity – 4TB Disks / 7200 RPM | E48VTNS192N/4 |
E60VT with 27TB capacity – 450GB SAS Disks / 15000 RPM | E60VTNS27P0/450 |
E60VT with 36TB capacity – 600GB SAS Disks / 15000 RPM | E60VTNS36P0/600 |
E60VT with 120TB capacity – 2TB Disks / 7200 RPM | E60VTNS120N/2 |
E60VT with 180TB capacity – 3TB Disks / 7200 RPM | E60VTNS180N/3 |
E60VT with 240TB capacity – 4TB Disks / 7200 RPM | E60VTNS240N/4 |
NST Storage Units | |
E-Series V Expansion Units | Part Number |
Maximum 2 expansion units per 6Gb/s E-Series head unit (expansion units must be the same as head units). | |
E18V Expansion Unit with 8.1TB capacity – 450GB SAS Disk / 15000 RPM | E18XVN8P1/450 |
E18V Expansion Unit with 10.8TB capacity – 600GB SAS Disk / 15000 RPM | E18XVN10P8/600 |
E18V Expansion Unit with 36TB capacity – 2TB Disk / 7200 RPM | E18XVN36N/2 |
E18V Expansion Unit with 54TB capacity – 3TB Disk / 7200 RPM | E18XVN54N/3 |
E18V Expansion Unit with 72TB capacity – 4TB Disk / 7200 RPM | E18XVN72N/4 |
E48VT Expansion Unit with 21.6TB capacity- 450GB SAS Disk / 15000 RPM | E48XVN21P6/450 |
E48VT Expansion Unit with 28.8TB capacity – 600GB SAS Disk / 15000 RPM | E48XVN28P8/600 |
E48VT Expansion Unit with 43.2TB capacity – 900GB Disks / 10000 RPM | E48XVN43J2/900 |
E48VT Expansion Unit with 96TB capacity – 2TB Disk / 7200 RPM | E48XVN96N/2 |
E48VT Expansion Unit with 144TB capacity – 3TB Disk / 7200 RPM | E48XVN144N/3 |
E48VT Expansion Unit with 192TB capacity – 4TB Disk / 7200 RPM | E48XVN192N/4 |
E60VT Expansion Unit with 27TB capacity- 450GB SAS Disk / 15000 RPM | E60XVN27P0/450 |
E60VT Expansion Unit with 36TB capacity- 600GB SAS Disk / 15000 RPM | E60XVN36P0/600 |
E60VT Expansion Unit with 120TB capacity – 2TB Disk / 7200 RPM | E60XVN120N/2 |
E60VT Expansion Unit with 180TB capacity – 3TB Disk / 7200 RPM | E60XVN180N/3 |
E60VT Expansion Unit with 240TB capacity – 4TB Disk / 7200 RPM | E60XVN240N/4 |
NOTE: SAS Cables included for all E-Series models | |
SAS-connected Storage Units | Part Number |
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 and NST6530 (max 9 chassis with expansions). Each head unit can have up to 2 additional cascading units. | |
NST224X with 14.4TB capacity – Includes 24x 600GB SAS 10k RPM HDDs and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X14J4/600 |
NST224X with 21.6TB capacity – Includes 24x 900GB SAS 10k RPM HDDs and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X21J6/900 |
NOTE: For each NST224X head unit, please add four (4) SAS CBL-010-xxxxMM cables from below. For each NST224X cascading unit, please add two (2) SAS CBL-010-xxxxMM cables from below | |
SAS-connected Flash Storage Units | |
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 and NST6530 (max 9 chassis with expansions). Each head unit can have up to 2 additional cascading units. | |
NST224X All Flash Array with 1.2TB capacity – Includes 6x 200GB eMLC SAS SSD and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X1Q2/200 |
NST224X All Flash Array with 2.4TB capacity – Includes 6x 400GB eMLC SAS SSD and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X2Q4/400 |
NOTE: For each NST224X head unit, please add four (4) SAS CBL-010-xxxxMM cables from below. For each NST224X cascading unit, please add two (2) SAS CBL-010-xxxxMM cables from below | |
NST224X 1.2TB Disk Pack – Includes 6x 200GB eMLC SAS SSD and license to use. Up to three (3) can be added to N224X1Q2/200 storage array | DP224X1Q2/200 |
NST224X 2.4TB Disk Pack – Includes 6x 400GB eMLC SAS SSD and license to use. Up to three (3) can be added to N224X2Q4/400 storage array | DP224X2Q4/400 |
NST224X Hardware & Software Support | Part Number |
**All components must be under the same support level** | |
MUST select quantity 1 per N224X-1P2/200F and each additional disk pack. MUST select quantity 2 per N224X-2P4/400F and each additional disk packs. | |
Basic Support – Annual Advance Shipped by NBD, Self Install FRU, Pricing per 1.2TB of SSD | |
Basic Support, Annual – Per 1.2 TB | OSB-DP224F-1P2T |
Enterprise Support – On-Site NBD, Pricing per 1.2TB of SSD | |
Enterprise Support, Annual – Per 1.2 TB | OSE-DP224F-1P2T |
Premium and Concierge Support – 4-Hour Response, Select GEO, Pricing per 1.2TB of SSD | |
Premium and Concierge Support, Annual – Per 1.2 TB | OSP-DP224F-1P2T |
Switches | Part Number |
NST5000 SAS Expansion Switch Connectivity Pack for NST5500 and NST6530 only, for connection to 7 storage head units (Includes 2xSAS Switch – 1x1U Mounting Tray) | NST-SASXSW-CP |
NOTE: Add four (4) SAS cables from below | |
Cables | Part Number |
SAS SFF8088 to SFF8088 SAS, 2.0 Meters | CBL-010-2000MM |
SAS SFF8088 to SFF8088 SAS, 3.0 Meters | CBL-010-3000MM |
SAS SFF8088 to SFF8088 SAS, 5.0 Meters | CBL-010-5000MM |
NST6000 FASTier OPTIONS (All systems configured with more than 1.8TB of FASTier must have 96GB of physical RAM per controller) | |
For NST6000 Series Including Metro Cluster | Part Number |
200GB FASTier read only – eMLC SSDs – Class 1 | FT6K-200G-EM-C1 |
400GB FASTier read only – eMLC SSDs – Class 1 | FT6K-400G-EM-C1 |
NOTE: The above FASTier packs include 2 devices (one per controller) and deliver indicated usable FASTier capacity. FASTier spare kits, in the Spare Kits tab, only include 1 device. | |
NST6000 SPARE KITS | Part Number |
Controller Parts | |
Spare Kit, Chassis – NST6300 | SK-CHA6300 |
Spare Kit, Chassis – NST6500 | SK-CHA6500 |
Spare Kit, Chassis – NST6700 | SK-CHA6700 |
Spare Kit, PSU – 750W AC for NST6000s | SK-PSU6K |
Spare Kit, Vault Module, 120V | SK-VM6K |
Spare Kit, Vault Module, 208/203V | SK-VM6KG |
Spare Disks | |
Spare Kit, Drive – SSD eMLC, 100GB Internal | SK-DSK6-100INTER |
Spare Kit, Drive – SSD eMLC, 200GB FASTier – Class 1 | SK-DSK6-200EMC1 |
Spare Kit, Drive – SSD eMLC, 400GB FASTier – Class 1 | SK-DSK6-400EMC1 |
HBAs | |
RJ-45 port 10GBASE-T IO module, based on Intel® Ethernet Controller X540 | NST6K-10GR-2P |
SFP+ port 10GbE IO module based on Intel® 82599 10 Gigabit Ethernet Controller | NST6K-10GS-2P |
10GbE NIC with dual RJ-45 interfaces, includes license to use | NST-10GR-2P |
10GbE NIC with dual SFP+ SR interfaces, includes license to use | NST-10GS-2P |
1GigE, Dual-port NIC, RJ-45 interfaces, includes license to use | NST-1GR-2P |
1GigE, Quad-port NIC, RJ-45 interfaces, includes license to use | NST-1GR-4P |
Fibre Channel Dual-Port Host Connectivity Card | NST6K-FC8-H2P |
Fibre Channel Quad-Port Host Connectivity Card | NST6K-FC8-H4P |
[restab title=”NST Service Programs”]
NST Service Program Details | ||||
Annual Agreements | Basic | Enterprise | Premium | Concierge |
Select locations only | Select locations only | |||
Hardware Replacement | Advance Replacement Ship NBD by two day air, Self Installed FRU | NBD On-Site | 4-Hour Response On-Site | 4-Hour Response On-Site |
Software Support Email | Nexsan Business Hours | 7×24 | 7×24 | 7×24 |
Phone Support (Remote) | Nexsan Business Hours | 7×24 | 7×24 | 7×24 |
Severity 1 Response (Remote) | 4-Business Hours | 4-Hour | 2-Hour | 1-Hour |
Severity 2/3 Response (Remote) | 6-Business Hours | 4 / 8-Business Hours | 4-Hour | 2-Hours |
Software Updates (bug fixes, minor releases) | Yes | Yes | Yes | Yes |
Software Upgrades (new features, bug fixes) | No | Yes | Yes | Yes |
Hardware Monitoring and auto-dispatch | No | No | No | Yes |
Assigned TAM, rapid path to answers | No | No | No | Yes |
Monthly Health Check | No | No | No | Yes |
Twice Annual capacity and performance review | No | No | No | Yes |