Nexsan_byImation_logo-thumb                                                             Call (800) 663-5523 for a Quote or Additional Information

MST6000MC

Get convergence, performance and scalability in a compact, fully unified hybrid storage system that can grow with your organization. The Nexsan NST Hybrid Storage system simultaneously supports Fibre Channel, iSCSI, NFS, CIFS, SMB and FTP protocols within a single storage operating system leveraging DRAM and SSDs to create a caching tier called FASTier™. With FASTier, Nexsan NST Hybrid Storage System is able to support the most demanding block-level SAN and file-level NAS workloads within one system, effectively solving your SAN versus NAS debate.

Hybrid Storage  is defined as a combination of solid-state disk (SSD) and hard disk drives (HDD) in a single storage system.

Use SSD to increase the cache memory pool so that I/Os are accelerated before they go through the controller to the back-end disk drives. The larger the cache memory pool, the greater the likelihood of getting a cache hit without having to access the back-end disks—which results in greater application performance.

The Nexsan NST6000MC metro storage cluster is an integrated high availability and disaster recovery solution that extends data replication and failover capability from within a data center to remote sites. The NST6000MC metro storage cluster system is a unified storage system that supports both SAN and NAS protocols while leveraging the power of solid-state storage to accelerate the read performance of the underlying SAS and SATA drives housed in efficient Fibre Channel-connected E-Series storage arrays.

[restabs alignment=”osc-tabs-left” responsive=”false”]
[restab title=”Overview” active=”active”]

The Nexsan NST6000MC Metro Storage Cluster solution meets the need of mid-market and enterprise customers to protect and improve the availability of mission-critical applications and their data. It delivers a compact, yet scalable, integrated high availability and disaster recovery solution that extends data replication and failover capability from within a data center to a campus site or to a metro site located up to 10km away.

As part of the NST6000 unified hybrid storage portfolio, the NST6000MC supports both SAN and NAS protocols while leveraging the power of solid-state storage to accelerate the read performance of the underlying SAS and SATA drives housed in efficient Fibre Channel-connected E-Series storage arrays. The net result is a lower cost-per-I/O and a lower total cost of ownership.

MAJOR FEATURES INCLUDE:

The NST6000MC Metro Storage Cluster is positioned both for the mid-market and the enterprise. There are three cluster controller node models: the NST6330, the NST6530 and the NST6730.

[/restab]
[restab title=”Specifications”]

System Capacities

Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise

 NST6530
NST6000 System Form Factor
NST6000 Controllers
NST6000 Vault Protection Modules
6U
2 x 2U = 4U
2 x 1U = 2U
NST6000 System CPU
Type | Cores
Xeon | 24 Cores
12 per Controller
NST6000 System Memory (DRAM)
Basic| Premium
192 GB | 384 GB
96 GB | 192 GB per Controller
FASTier Fault Tolerant
Write Cache Capacity
32 GB
64 GB Mirrored Capacity in System
FASTier Read Cache Capacity
Standard | Maximum
4.4 TB | 9.2 TB
Maximum FASTier
Read Cache Devices
Up to 46 Read Cache Devices
FASTier
Read Cache Types
200, 400, 800GB eMLC | 100, 200GB SLC
RAID Levels RAID 5, RAID 6, RAID 10

Connectivity

Data listed in the table refers to a single 2U NST6000 Controller unless indicated otherwise

NST6530
NST6000 Host Connectivity
1GbE I/O Embedded
STANDARD CONFIGURATION
4 – port 1GbE
1 is management. 1 is reserved.
10 GbE I/O PCIe Card
STANDARD CONFIGURATION
(1) dual-port 10GbE
PCIe Slots for Additional
Host Connectivity
2
1GbE PCIe Cards
OPTIONAL
dual-port or quad-port 1GbE
10GbE PCIe Cards
OPTIONAL
dual-port 10GbE
8 Gb/s FC I/O PCIe Cards
OPTIONAL
dual-port or quad-port 8Gb
1GbE I/O Ports 2 to 10
10GbE I/O Ports 2 to 6
8 Gb/s FC I/O Ports 0 to 8
NST6000 SAS Storage Connectivity: Nexsan E-Series V Arrays
6 Gb/s SAS
STANDARD CONFIGURATION
# of SAS Ports 6 ports. 4 lanes (links) per port.
Total SAS Bandwidth = 144 Gb/s.
(1) dual-port
(1) quad-port
PCIe Card Type
Nexsan E-Series V Storage
# of RAID Arrays | Expansion Units  
3 E-Series V Arrays
6 Expansion Units
9 Total E-Series
6 Gb/s SAS Switch
OPTIONAL
16 Mini-SAS wide ports
4 lanes (links) per port
NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure
6 Gb/s SAS
STANDARD CONFIGURATION
# of SAS Ports 6 ports. 4 lanes (links) per port.
Total SAS Bandwidth = 144 Gb/s.
 PCIe Card Type
Nexsan NST224X
Number of Enclosures
(1) dual-port
(1) quad-port
Up to 9.
6 Gb/s SAS Switch
OPTIONAL
16 Mini-SAS wide ports4 SAS lanes per port

System Storage Capacity

Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise. Additional capacities are available for the NL-SAS HDDs and Performance- SAS HDDs listed below.

    NST6530
NST6000 SAS Storage Connectivity: Nexsan E-Series V Array
Nexsan E-Series V RAID Array
Number of Head Units 
STANDARD CONFIG WITH SAS SWITCH
3 E-Series Arrays 7 E-Series Arrays
6 Expansion Units 14 Expansion Units
9 Total E-Series 21 Total E-Series
E-Series V Arrays
Types Available 
E18: 18 3.5” drives in 2U
E48: 48 3.5” drives in 4U
E60: 60 3.5” drives in 4U
E-Series V Expansion Units
Types Available 
E18X: 18 3.5” drives in 2U
E48X: 48 3.5” drives in 4U
E60X: 60 3.5” drives in 4U
Max 3.5″ NL-SAS HDD Capacity
Based on use of E60 and E60X
Number HDD | Capacity @ 4TB/HDD
STANDARD CONFIG WITH SAS SWITCH
540 NL-SAS Drives 1260 NL-SAS Drives
2,160 TB 5,040 TB
Max 3.5″ Performance-SAS HDD Capacity
Based on use of E60 and E60X
Number HDD | Capacity @ 600GB/HDD
STANDARD CONFIG WITH SAS SWITCH
540 SAS Drives 1260 SAS Drives
324 TB 756 TB
NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure
HDD 2.5″ 10K Performance SAS HDDs Number of NST224X Enclosures Up to 9. 24 HDDs / Enclosure.
Max Performance – SAS HDD Capacity
Number HDD | Capacity @ 1.2 TB/HDD
216 Drives | 259.2TB
eMLC SSDs Number of NST224X Enclosures Up to 9. 24 SSDs / Enclosure.
Max External SSD Capacity
Number SDD | Capacity @ 800 GB/SDD
216 Drives | 172.8TB

System Storage Services

Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise

 NST6530
Client Support  Linux, OS X, Unix, WindowsESXi, Hyper-V, XenServer
Storage Services  Fibre Channel, iSCSI, NFS, CIFS,SMB, FTP
Maximum Single File Size 16 TB
Max NFS Shares 512
Max CIFS Shares 512
Max Snapshots Per Share 2,048
Maximum LUN Size 64 TB
Max LUNs Per Target 255
System Max LUNs  255 – Fibre Channel
1,024 – iSCSI
Max Snapshots per LUN 2,048

Environmentals. Dimensions.

Data listed in the table refers to single 2U NST6000 Controller unless indicated otherwise

 NST6530
Operating Temperature 10-35C, 50-95F
Operating Humidity 20-95% (non-condensing)
U of Rack Space 2U
Height 3.5in, 8.76cm
Width 17.2in, 43.8cm
Depth 27.87in, 70.78cm
Weight >40lbs, >18.1Kg
# hot swappable power supplies 2
Maximum Power/Controller Node < 430 W
 Voltage, Frequency    Voltage (110): 90-132V; Frequency47-63 Hz
Voltage (220): 180-246V; Frequency47-63 Hz
Heat Dissipation 1467 btu/hr

System Storage Services

Data listed in the table refers to a single NST6000 Vault Protection Module unless indicated otherwise

 NST6000 Vault Protection Module
120 V 230 V
Dimensions
Dimensions (H x W x D, inches) 1.7 (1U) x 17.2 x 21.8 1.7 (1U) x 17.2 x 21.8
Dimensions (H x W x D, mm) 43.2 x 438 x 554 43.2 x 438 x 554
Weight (kg) 20.0 19.36
Weight (lbs) 44.1 42.7
Battery
Battery Description Sealed. Lead-acid. Maintenance free.
Battery Management Battery life management and advanced warning for battery replacement
Electrical
Input / Output Connections  Input: (1) NEMA 5-15P; Output: (5)NEMA 5-15R Input: (1) C14; Output: (6) C13
Input / Output Nominal Voltage 120V (adjustable to 100/120/125 V) 230V (adjustable to 200/208/220/230/240 V)
Input / Output Frequency 50 / 60 Hz 50 / 60 Hz
On Utility Voltage Regulation 102 – 132 V 102 – 132 V
On Battery Voltage Regulation – 10% – + 6% of Nominal – 10% – + 6% of Nominal
Communications
User Interface LCD Graphical Display
LEDs Load protected, on battery and fault
Communication Card Slots One Slot
Other
RoHS Compliance Yes
Heat Dissipation (BTU) Line: 113, Battery 714
Audible Noise < 45 dB at 1 meter
Operating Temperature 0-40C, 32-104F
Performance – Safety – EMC UL 1778, UL497A
Safety Markings cULus, CE
EMC Markings IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B
Storage Temperature -15 – 40C, 5-10F
Relative Humidity 0-95% (non-condensing)

 

[/restab]
[restab title=”NST Service”]

NST Service Program Details
Annual Agreements Basic Enterprise Premium Concierge
Select locations only Select locations only
Hardware Replacement Advance Replacement Ship NBD by two day air, Self Installed FRU NBD On-Site 4-Hour Response On-Site 4-Hour Response On-Site
Software Support Email Nexsan Business Hours 7×24 7×24 7×24
Phone Support (Remote) Nexsan Business Hours 7×24 7×24 7×24
Severity 1 Response (Remote) 4-Business Hours 4-Hour 2-Hour 1-Hour
Severity 2/3 Response (Remote) 6-Business Hours 4 / 8-Business Hours 4-Hour 2-Hours
Software Updates (bug fixes, minor releases) Yes Yes Yes Yes
Software Upgrades (new features, bug fixes) No Yes Yes Yes
Hardware Monitoring and auto-dispatch No No No Yes
Assigned TAM, rapid path to answers No No No Yes
Monthly Health Check No No No Yes
Twice Annual capacity and performance review No No No Yes

[/restab]

[restab title=”Documents”]

   Datasheet

   Specifications

[/restab][/restabs]

[restabs alignment=”osc-tabs-left” responsive=”false” tabheadcolor=”#dd3333″]
[restab title=”NST6000MC” active=”active”]

NST6000 Metro Cluster Configuration Systems
NST6000-MC storage systems all contain Dual controllers. Includes core operating system, Data Protection Package and E-Centre management platform software licenses. Requires the addition of Storage Connectivity Option(s) from below.
NST6330-MC Unified Storage Part Number
NST6330 Metro Cluster Storage System, two four-core Intel Xeon processors, 48GB RAM and two GigE ports per controller – Dual Controllers – (120V or 230V). Supports up to 4 storage head units. NST6330MC-DC
NST6530-MC Unified Storage
NST6530 Metro Cluster Storage System, two six-core Intel Xeon processors, 96GB RAM and two GigE ports per controller – Dual Controllers – (120V or 230V). Supports up to 6 storage head units. NST6530MC-DC
NST6730-MC Unified Storage
NST6730 Metro Cluster Storage System, two eight-core Intel Xeon processors, 192GB RAM and two GigE ports per controller – Dual Controllers – (120V or 230V). Supports up to 8 storage head units. NST6730MC-DC
Storage Connectivity                                                                                            Part Number
NST6330-MC Storage Connectivity Option (Must Select One or Two)
Fibre Channel Dual-Port Connectivity Pack – Adds two dual-port 8Gb/s FC ports per controller for connection to a synchronously replicated pair of FC-connected E18, E48 or E60 storage unit (plus expansion unit). Includes license to use. NST6K-FC8-DPMCP
NST6530-MC Storage Connectivity Option  (Must Select One or Two, Maximum One Quad-Port Pack)
Fibre Channel Dual-Port Connectivity Pack – Adds two dual-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48 or E60 storage unit (plus expansion unit). Includes license to use. NST6K-FC8-DPMCP
Fibre Channel Quad-Port Connectivity Pack– Adds two quad-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48, or E60 storage units (plus expansion units) and license to use. NST6K-FC8-QPMCP
NST6730-MC Storage Connectivity Option  (Must Select One or Two)
Fibre Channel Dual-Port Connectivity Pack – Adds two dual-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48 or E60 storage unit (plus expansion unit). Includes license to use. NST6K-FC8-DPMCP
Fibre Channel Quad-Port Connectivity Pack– Adds two quad-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48, or E60 storage units (plus expansion units) and license to use. NST6K-FC8-QPMCP
SFP+ Single Mode Transceiver 8Gb/10km – (Must select quantity 1 for each FC port on both E-Series and NST) NST6K-8GS-SMT
Host Connectivity (Select Up to One)
Pair of Dual RJ-45 port 10GBASE-T IO module, based on Intel® Ethernet Controller X540 NST6K-10GR-DPCP
Pair of Dual SFP+ port 10GbE IO module based on Intel® 82599 10 Gigabit Ethernet Controller NST6K-10GS-DPCP
Host Connectivity (Select Maximum Two)
Pair of 10GbE NIC with dual RJ-45 interfaces, includes license to use  NST-10GR-DPCP
Pair of 10GbE NIC with dual SFP+ SR interfaces, includes license to use  NST-10GS-DPCP
Pair of 1GigE, Dual-port NIC, RJ-45 interfaces, includes license to use  NST-1GR-DPCP
Pair of 1GigE, Quad-port NIC, RJ-45 interfaces, includes license to use  NST-1GR-QPCP
FASTier Performance Boost (Optional) – Use NST6000 FASTier TAB and select accordingly for NST6000-MC model
Performance Packs
NST6300MC Part Number
Performance Pack for NST6300MC.  Increases controller RAM from 48GB to 96GB. NST6300-PP1
NST6500MC
Performance Pack for NST6500MC.   Increases controller RAM from 96GB to 192GB. NST6500-PP1
Storage Units
Fibre Channel-connect E-Series Part Number
See NST Storage Unites tab to configure storage
NST6000 Hardware & Software Support Part Number
**All components must be under the same support level**
Basic Support – Annual Advance Shipped by NBD, Self Install FRU, Pricing per Metro-Cluster
Basic Support, Annual – Tier 1 License (16TB) OSB-NST6K-16T
Basic Support, Annual – Tier 2 License (16TB – 64TB) OSB-NST6K-64T
Basic Support, Annual – Tier 3 License (64TB – 128TB) OSB-NST6K-128T
Basic Support, Annual – Tier 4 License (128TB – 256TB) OSB-NST6K-256T
Basic Support, Annual – Tier 5 License (256TB – 512TB) OSB-NST6K-512T
Basic Support, Annual – Tier 6 License (512TB – 1024TB) OSB-NST6K-1P
Basic Support, Annual – Tier 7 License (1024TB – 2048TB) OSB-NST6K-2P
Basic Support, Annual – Tier 8 License (2048TB – 4096TB) OSB-NST6K-4P
Basic Support, Annual – Tier 9 License (4096TB – 8192TB) OSB-NST6K-8P
Enterprise Support – On-Site NBD, Pricing per System per Site
Enterprise Support, Annual – Tier 1 License (16TB) OSE-NST6K-16T
Enterprise Support, Annual – Tier 2 License (16TB – 64TB) OSE-NST6K-64T
Enterprise Support, Annual – Tier 3 License (64TB – 128TB) OSE-NST6K-128T
Enterprise Support, Annual – Tier 4 License (128TB – 256TB) OSE-NST6K-256T
Enterprise Support, Annual – Tier 5 License (256TB – 512TB) OSE-NST6K-512T
Enterprise Support, Annual – Tier 6 License (512TB – 1024TB) OSE-NST6K-1P
Enterprise Support, Annual – Tier 7 License (1024TB – 2048TB) OSE-NST6K-2P
Enterprise Support, Annual – Tier 8 License (2048TB – 4096TB) OSE-NST6K-4P
Enterprise Support, Annual – Tier 9 License (4096TB – 8192TB) OSE-NST6K-8P
NST6000 Hardware & Software Support
**All components must be under the same support level**
Premium Support – 4-Hour Response, Select GEO, Pricing per Metro-Cluster
Premium Support, Annual – Tier 1 License (16TB)* OSP-NST6K-16T
Premium Support, Annual – Tier 2 License (16TB – 64TB)* OSP-NST6K-64T
Premium Support, Annual – Tier 3 License (64TB – 128TB)* OSP-NST6K-128T
Premium Support, Annual – Tier 4 License (128TB – 256TB)* OSP-NST6K-256T
Premium Support, Annual – Tier 5 License (256TB – 512TB)* OSP-NST6K-512T
Premium Support, Annual – Tier 6 License (512TB – 1024TB)* OSP-NST6K-1P
Premium Support, Annual – Tier 7 License (1024TB – 2048TB)* OSP-NST6K-2P
Premium Support, Annual – Tier 8 License (2048TB – 4096TB)* OSP-NST6K-4P
Premium Support, Annual – Tier 9 License (4096TB – 8192TB)* OSP-NST6K-8P
Concierge Support – 4-Hour Response, Managed Services, Select GEO, Pricing per Metro-Cluster
Concierge Support, Annual – Tier 1 License (16TB)* OSC-NST6K-16T
Concierge Support, Annual – Tier 2 License (16TB – 64TB)* OSC-NST6K-64T
Concierge Support, Annual – Tier 3 License (64TB – 128TB)* OSC-NST6K-128T
Concierge Support, Annual – Tier 4 License (128TB – 256TB)* OSC-NST6K-256T
Concierge Support, Annual – Tier 5 License (256TB – 512TB)* OSC-NST6K-512T
Concierge Support, Annual – Tier 6 License (512TB – 1024TB)* OSC-NST6K-1P
Concierge Support, Annual – Tier 7 License (1024TB – 2048TB)* OSC-NST6K-2P
Concierge Support, Annual – Tier 8 License (2048TB – 4096TB)* OSC-NST6K-4P
Concierge Support, Annual – Tier 9 License (4096TB – 8192TB)* OSC-NST6K-8P
On-Site Installation
On-Site installation (per site) based on 1 day includes Travel applies to CONUS and W. Europe all other locations call. OSI-NST6K-STD
On-Site installation (per site) – Complex, based on Statement of Work. OSI-NST6K-PROF

[/restab]
[restab title=”NST Storage Units”]

NST Storage Units
Storage Unit option for FC or SAS for all NST5300s and NST5500s and FC only for all NST6000MCs and SAS only for the NST6530.
Existing customers with Legacy E-Series see Legacy Expansion Units tab to order expansion units.
Fibre Channel-connected 6Gb/s E-Series Storage Units Part Number
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 (max 9 chassis with expansions), maximum 4 head units can be added to NST6330MC, maximum 6 for NST6530MC, and maximum 8 for NST6730MC.
E18V with 8.1TB capacity– 450GB SAS Disk / 15000 RPM E18VHNJ8P1/450
E18V with 10.8TB capacity – 600GB SAS Disk / 15000 RPM E18VHNJ10P8/600
E18V with 36TB capacity – 2TB Disks / 7200 RPM E18VHNJ36N/2
E18V with 54TB capacity – 3TB Disks / 7200 RPM E18VHNJ54N/3
E18V with 72TB capacity – 4TB Disks / 7200 RPM E18VHNJ72N/4
E48VT with 21.6TB capacity – 450GB Disks / 15000 RPM E48VTNJ21P6/450
E48VT with 28.8TB capacity – 600GB Disks / 15000 RPM E48VTNJ28P8/600
E48VT with 43.2TB capacity – 900GB Disks / 10000 RPM E48VTNJ43J2/900
E48VT with 96TB capacity – 2TB Disks / 7200 RPM E48VTNJ96N/2
E48VT with 144TB capacity – 3TB Disks / 7200 RPM E48VTNJ144N/3
E48VT with 192TB capacity – 4TB Disks / 7200 RPM E48VTNJ192N/4
E60VT with 27TB capacity – 450GB Disks / 15000 RPM E60VTNJ27P0/450
E60VT with 36TB capacity – 600GB Disks / 15000 RPM E60VTNJ36P0/600
E60VT with 120TB capacity – 2TB Disks / 7200 RPM E60VTNJ120N/2
E60VT with 180TB capacity – 3TB Disks / 7200 RPM E60VTNJ180N/3
E60VT with 240TB capacity – 4TB Disks / 7200 RPM E60VTNJ240N/4
NOTE:   For each E60, E48 or E18 selected, please add four (4) LC-LC cables from below. (Does not apply to E60X, E48X or E18X expansion units.)
NOTE:   Metro Cluster units use single mode fibre provided by the customer.
Cables Part Number
Fiber Optic LC-LC cable, 3 Meters CBL-007-3.0M
Fiber Optic LC-LC cable, 5 Meters CBL-007-5.0M
SAS-connected 6Gb/s E-Series Storage Units
Maximum 2 storage units can be added to NST5300, maximum 3 for NST5500 and NST6530 (non-MC). Part Number
E18V with 8.1TB capacity– 450GB SAS Disk / 15000 RPM E18VHNS8P1/450
E18V with 10.8TB capacity – 600GB SAS Disk / 15000 RPM E18VHNS10P8/600
E18V with 36TB capacity – 2TB Disks / 7200 RPM E18VHNS36N/2
E18V with 54TB capacity – 3TB Disks / 7200 RPM E18VHNS54N/3
E18V with 72TB capacity – 4TB Disks / 7200 RPM E18VHNS72N/4
E48VT with 21.6TB capacity – 450GB SAS Disks / 15000 RPM E48VTNS21P6/450
E48VT with 28.8TB capacity – 600GB SAS Disks / 15000 RPM E48VTNS28P8/600
E48VT with 43.2TB capacity – 900GB Disks / 10000 RPM E48VTNS43J2/900
SAS-connected 6Gb/s E-Series Storage Units
Maximum 2 storage units can be added to NST5300, maximum 3 for NST5500 and NST6530 (non-MC). Part Number
E48VT with 96TB capacity – 2TB Disks / 7200 RPM E48VTNS96N/2
E48VT with 144TB capacity – 3TB Disks / 7200 RPM E48VTNS144N/3
E48VT with 192TB capacity – 4TB Disks / 7200 RPM E48VTNS192N/4
E60VT with 27TB capacity – 450GB SAS Disks / 15000 RPM E60VTNS27P0/450
E60VT with 36TB capacity – 600GB SAS Disks / 15000 RPM E60VTNS36P0/600
E60VT with 120TB capacity – 2TB Disks / 7200 RPM E60VTNS120N/2
E60VT with 180TB capacity – 3TB Disks / 7200 RPM E60VTNS180N/3
E60VT with 240TB capacity – 4TB Disks / 7200 RPM E60VTNS240N/4
NST Storage Units
E-Series V Expansion Units Part Number
Maximum 2 expansion units per 6Gb/s E-Series head unit (expansion units must be the same as head units).
E18V Expansion Unit with 8.1TB capacity450GB SAS Disk / 15000 RPM E18XVN8P1/450
E18V Expansion Unit with 10.8TB capacity – 600GB SAS Disk / 15000 RPM E18XVN10P8/600
E18V Expansion Unit with 36TB capacity2TB Disk / 7200 RPM E18XVN36N/2
E18V Expansion Unit with 54TB capacity3TB Disk / 7200 RPM E18XVN54N/3
E18V Expansion Unit with 72TB capacity4TB Disk / 7200 RPM E18XVN72N/4
E48VT Expansion Unit with 21.6TB capacity– 450GB SAS Disk / 15000 RPM E48XVN21P6/450
E48VT Expansion Unit with 28.8TB capacity600GB SAS Disk / 15000 RPM E48XVN28P8/600
E48VT Expansion Unit with 43.2TB capacity – 900GB Disks / 10000 RPM E48XVN43J2/900
E48VT Expansion Unit with 96TB capacity 2TB Disk / 7200 RPM E48XVN96N/2
E48VT Expansion Unit with 144TB capacity 3TB Disk / 7200 RPM E48XVN144N/3
E48VT Expansion Unit with 192TB capacity 4TB Disk / 7200 RPM E48XVN192N/4
E60VT Expansion Unit with 27TB capacity– 450GB SAS Disk / 15000 RPM E60XVN27P0/450
E60VT Expansion Unit with 36TB capacity– 600GB SAS Disk / 15000 RPM E60XVN36P0/600
E60VT Expansion Unit with 120TB capacity 2TB Disk / 7200 RPM E60XVN120N/2
E60VT Expansion Unit with 180TB capacity 3TB Disk / 7200 RPM E60XVN180N/3
E60VT Expansion Unit with 240TB capacity 4TB Disk / 7200 RPM E60XVN240N/4
NOTE:  SAS Cables included for all E-Series models
SAS-connected Storage Units Part Number
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 and NST6530 (max 9 chassis with expansions). Each head unit can have up to 2 additional cascading units.
NST224X with 14.4TB capacity – Includes 24x 600GB SAS 10k RPM HDDs and license to use. Can be used as NST224X head unit or cascading from a NST224X N224X14J4/600
NST224X with 21.6TB capacity – Includes 24x 900GB SAS 10k RPM HDDs and license to use. Can be used as NST224X head unit or cascading from a NST224X N224X21J6/900
NOTE:   For each NST224X head unit, please add four (4) SAS CBL-010-xxxxMM cables from below. For each NST224X cascading unit, please add two (2) SAS CBL-010-xxxxMM cables from below
SAS-connected Flash Storage Units
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 and NST6530 (max 9 chassis with expansions). Each head unit can have up to 2 additional cascading units.
NST224X All Flash Array with 1.2TB capacity – Includes 6x 200GB eMLC SAS SSD and license to use. Can be used as NST224X head unit or cascading from a NST224X N224X1Q2/200
NST224X All Flash Array with 2.4TB capacity – Includes 6x 400GB eMLC SAS SSD and license to use. Can be used as NST224X head unit or cascading from a NST224X N224X2Q4/400
NOTE:   For each NST224X head unit, please add four (4) SAS CBL-010-xxxxMM cables from below. For each NST224X cascading unit, please add two (2) SAS CBL-010-xxxxMM cables from below
NST224X 1.2TB Disk Pack – Includes 6x 200GB eMLC SAS SSD and license to use. Up to three (3) can be added to N224X1Q2/200 storage array DP224X1Q2/200
NST224X 2.4TB Disk Pack – Includes 6x 400GB eMLC SAS SSD and license to use. Up to three (3) can be added to N224X2Q4/400 storage array DP224X2Q4/400
NST224X Hardware & Software Support Part Number
**All components must be under the same support level**
MUST select quantity 1 per N224X-1P2/200F and each additional disk pack. MUST select quantity 2 per N224X-2P4/400F and each additional disk packs.
Basic Support – Annual Advance Shipped by NBD, Self Install FRU, Pricing per 1.2TB of SSD
Basic Support, Annual – Per 1.2 TB OSB-DP224F-1P2T
Enterprise Support – On-Site NBD, Pricing per 1.2TB of SSD
Enterprise Support, Annual – Per 1.2 TB OSE-DP224F-1P2T
Premium and Concierge Support – 4-Hour Response, Select GEO, Pricing per 1.2TB of SSD
Premium and Concierge Support, Annual – Per 1.2 TB OSP-DP224F-1P2T
Switches Part Number
NST5000 SAS Expansion Switch Connectivity Pack for NST5500 and NST6530 only, for connection to 7 storage head units (Includes 2xSAS Switch – 1x1U Mounting Tray)  NST-SASXSW-CP
NOTE: Add four (4) SAS cables from below
Cables Part Number
SAS SFF8088 to SFF8088 SAS, 2.0 Meters  CBL-010-2000MM
SAS SFF8088 to SFF8088 SAS, 3.0 Meters  CBL-010-3000MM
SAS SFF8088 to SFF8088 SAS, 5.0 Meters  CBL-010-5000MM

[/restab][/restabs]