Get convergence, performance and scalability in a compact, fully unified hybrid storage system that can grow with your organization. The Nexsan NST Hybrid Storage system simultaneously supports Fibre Channel, iSCSI, NFS, CIFS, SMB and FTP protocols within a single storage operating system leveraging DRAM and SSDs to create a caching tier called FASTier™. With FASTier, Nexsan NST Hybrid Storage System is able to support the most demanding block-level SAN and file-level NAS workloads within one system, effectively solving your SAN versus NAS debate.
Use SSD to increase the cache memory pool so that I/Os are accelerated before they go through the controller to the back-end disk drives. The larger the cache memory pool, the greater the likelihood of getting a cache hit without having to access the back-end disks—which results in greater application performance.
The Nexsan NST6000MC metro storage cluster is an integrated high availability and disaster recovery solution that extends data replication and failover capability from within a data center to remote sites. The NST6000MC metro storage cluster system is a unified storage system that supports both SAN and NAS protocols while leveraging the power of solid-state storage to accelerate the read performance of the underlying SAS and SATA drives housed in efficient Fibre Channel-connected E-Series storage arrays.
[restabs alignment=”osc-tabs-left” responsive=”false”]
[restab title=”Overview” active=”active”]
The Nexsan NST6000MC Metro Storage Cluster solution meets the need of mid-market and enterprise customers to protect and improve the availability of mission-critical applications and their data. It delivers a compact, yet scalable, integrated high availability and disaster recovery solution that extends data replication and failover capability from within a data center to a campus site or to a metro site located up to 10km away.
As part of the NST6000 unified hybrid storage portfolio, the NST6000MC supports both SAN and NAS protocols while leveraging the power of solid-state storage to accelerate the read performance of the underlying SAS and SATA drives housed in efficient Fibre Channel-connected E-Series storage arrays. The net result is a lower cost-per-I/O and a lower total cost of ownership.
The NST6000MC Metro Storage Cluster is positioned both for the mid-market and the enterprise. There are three cluster controller node models: the NST6330, the NST6530 and the NST6730.
[/restab]
[restab title=”Specifications”]
Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise
NST6530 | |
---|---|
NST6000 System Form Factor NST6000 Controllers NST6000 Vault Protection Modules |
6U 2 x 2U = 4U 2 x 1U = 2U |
NST6000 System CPU Type | Cores |
Xeon | 24 Cores 12 per Controller |
NST6000 System Memory (DRAM) Basic| Premium |
192 GB | 384 GB 96 GB | 192 GB per Controller |
FASTier Fault Tolerant Write Cache Capacity |
32 GB 64 GB Mirrored Capacity in System |
FASTier Read Cache Capacity Standard | Maximum |
4.4 TB | 9.2 TB |
Maximum FASTier Read Cache Devices |
Up to 46 Read Cache Devices |
FASTier Read Cache Types |
200, 400, 800GB eMLC | 100, 200GB SLC |
RAID Levels | RAID 5, RAID 6, RAID 10 |
Data listed in the table refers to a single 2U NST6000 Controller unless indicated otherwise
NST6530 | ||
---|---|---|
NST6000 Host Connectivity | ||
1GbE I/O Embedded STANDARD CONFIGURATION |
4 – port 1GbE 1 is management. 1 is reserved. |
|
10 GbE I/O PCIe Card STANDARD CONFIGURATION |
(1) dual-port 10GbE | |
PCIe Slots for Additional Host Connectivity |
2 | |
1GbE PCIe Cards OPTIONAL |
dual-port or quad-port 1GbE | |
10GbE PCIe Cards OPTIONAL |
dual-port 10GbE | |
8 Gb/s FC I/O PCIe Cards OPTIONAL |
dual-port or quad-port 8Gb | |
1GbE I/O Ports | 2 to 10 | |
10GbE I/O Ports | 2 to 6 | |
8 Gb/s FC I/O Ports | 0 to 8 | |
NST6000 SAS Storage Connectivity: Nexsan E-Series V Arrays | ||
6 Gb/s SAS STANDARD CONFIGURATION |
# of SAS Ports | 6 ports. 4 lanes (links) per port. Total SAS Bandwidth = 144 Gb/s. |
(1) dual-port (1) quad-port |
||
PCIe Card Type | ||
Nexsan E-Series V Storage # of RAID Arrays | Expansion Units |
3 E-Series V Arrays 6 Expansion Units 9 Total E-Series |
|
6 Gb/s SAS Switch OPTIONAL |
16 Mini-SAS wide ports 4 lanes (links) per port |
|
NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure | ||
6 Gb/s SAS STANDARD CONFIGURATION |
# of SAS Ports | 6 ports. 4 lanes (links) per port. Total SAS Bandwidth = 144 Gb/s. |
PCIe Card Type | ||
Nexsan NST224X Number of Enclosures |
||
(1) dual-port (1) quad-port |
||
Up to 9. | ||
6 Gb/s SAS Switch OPTIONAL |
16 Mini-SAS wide ports4 SAS lanes per port |
Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise. Additional capacities are available for the NL-SAS HDDs and Performance- SAS HDDs listed below.
NST6530 | |||
---|---|---|---|
NST6000 SAS Storage Connectivity: Nexsan E-Series V Array | |||
Nexsan E-Series V RAID Array Number of Head Units |
STANDARD CONFIG | WITH SAS SWITCH | |
3 E-Series Arrays | 7 E-Series Arrays | ||
6 Expansion Units | 14 Expansion Units | ||
9 Total E-Series | 21 Total E-Series | ||
E-Series V Arrays Types Available |
E18: 18 3.5” drives in 2U | ||
E48: 48 3.5” drives in 4U | |||
E60: 60 3.5” drives in 4U | |||
E-Series V Expansion Units Types Available |
E18X: 18 3.5” drives in 2U | ||
E48X: 48 3.5” drives in 4U | |||
E60X: 60 3.5” drives in 4U | |||
Max 3.5″ NL-SAS HDD Capacity Based on use of E60 and E60X Number HDD | Capacity @ 4TB/HDD |
STANDARD CONFIG | WITH SAS SWITCH | |
540 NL-SAS Drives | 1260 NL-SAS Drives | ||
2,160 TB | 5,040 TB | ||
Max 3.5″ Performance-SAS HDD Capacity Based on use of E60 and E60X Number HDD | Capacity @ 600GB/HDD |
STANDARD CONFIG | WITH SAS SWITCH | |
540 SAS Drives | 1260 SAS Drives | ||
324 TB | 756 TB | ||
NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure | |||
HDD 2.5″ 10K Performance SAS HDDs | Number of NST224X Enclosures | Up to 9. 24 HDDs / Enclosure. | |
Max Performance – SAS HDD Capacity Number HDD | Capacity @ 1.2 TB/HDD |
216 Drives | 259.2TB | ||
eMLC SSDs | Number of NST224X Enclosures | Up to 9. 24 SSDs / Enclosure. | |
Max External SSD Capacity Number SDD | Capacity @ 800 GB/SDD |
216 Drives | 172.8TB |
Data listed in the table refers to a single 6U NST6000 Appliance unless indicated otherwise
NST6530 | |
---|---|
Client Support | Linux, OS X, Unix, WindowsESXi, Hyper-V, XenServer |
Storage Services | Fibre Channel, iSCSI, NFS, CIFS,SMB, FTP |
Maximum Single File Size | 16 TB |
Max NFS Shares | 512 |
Max CIFS Shares | 512 |
Max Snapshots Per Share | 2,048 |
Maximum LUN Size | 64 TB |
Max LUNs Per Target | 255 |
System Max LUNs | 255 – Fibre Channel 1,024 – iSCSI |
Max Snapshots per LUN | 2,048 |
Data listed in the table refers to single 2U NST6000 Controller unless indicated otherwise
NST6530 | |
---|---|
Operating Temperature | 10-35C, 50-95F |
Operating Humidity | 20-95% (non-condensing) |
U of Rack Space | 2U |
Height | 3.5in, 8.76cm |
Width | 17.2in, 43.8cm |
Depth | 27.87in, 70.78cm |
Weight | >40lbs, >18.1Kg |
# hot swappable power supplies | 2 |
Maximum Power/Controller Node | < 430 W |
Voltage, Frequency | Voltage (110): 90-132V; Frequency47-63 Hz Voltage (220): 180-246V; Frequency47-63 Hz |
Heat Dissipation | 1467 btu/hr |
Data listed in the table refers to a single NST6000 Vault Protection Module unless indicated otherwise
NST6000 Vault Protection Module | ||
---|---|---|
120 V | 230 V | |
Dimensions | ||
Dimensions (H x W x D, inches) | 1.7 (1U) x 17.2 x 21.8 | 1.7 (1U) x 17.2 x 21.8 |
Dimensions (H x W x D, mm) | 43.2 x 438 x 554 | 43.2 x 438 x 554 |
Weight (kg) | 20.0 | 19.36 |
Weight (lbs) | 44.1 | 42.7 |
Battery | ||
Battery Description | Sealed. Lead-acid. Maintenance free. | |
Battery Management | Battery life management and advanced warning for battery replacement | |
Electrical | ||
Input / Output Connections | Input: (1) NEMA 5-15P; Output: (5)NEMA 5-15R | Input: (1) C14; Output: (6) C13 |
Input / Output Nominal Voltage | 120V (adjustable to 100/120/125 V) | 230V (adjustable to 200/208/220/230/240 V) |
Input / Output Frequency | 50 / 60 Hz | 50 / 60 Hz |
On Utility Voltage Regulation | 102 – 132 V | 102 – 132 V |
On Battery Voltage Regulation | – 10% – + 6% of Nominal | – 10% – + 6% of Nominal |
Communications | ||
User Interface | LCD Graphical Display | |
LEDs | Load protected, on battery and fault | |
Communication Card Slots | One Slot | |
Other | ||
RoHS Compliance | Yes | |
Heat Dissipation (BTU) | Line: 113, Battery 714 | |
Audible Noise | < 45 dB at 1 meter | |
Operating Temperature | 0-40C, 32-104F | |
Performance – Safety – EMC | UL 1778, UL497A | |
Safety Markings | cULus, CE | |
EMC Markings | IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B | |
Storage Temperature | -15 – 40C, 5-10F | |
Relative Humidity | 0-95% (non-condensing) |
[/restab]
[restab title=”NST Service”]
NST Service Program Details | ||||
Annual Agreements | Basic | Enterprise | Premium | Concierge |
Select locations only | Select locations only | |||
Hardware Replacement | Advance Replacement Ship NBD by two day air, Self Installed FRU | NBD On-Site | 4-Hour Response On-Site | 4-Hour Response On-Site |
Software Support Email | Nexsan Business Hours | 7×24 | 7×24 | 7×24 |
Phone Support (Remote) | Nexsan Business Hours | 7×24 | 7×24 | 7×24 |
Severity 1 Response (Remote) | 4-Business Hours | 4-Hour | 2-Hour | 1-Hour |
Severity 2/3 Response (Remote) | 6-Business Hours | 4 / 8-Business Hours | 4-Hour | 2-Hours |
Software Updates (bug fixes, minor releases) | Yes | Yes | Yes | Yes |
Software Upgrades (new features, bug fixes) | No | Yes | Yes | Yes |
Hardware Monitoring and auto-dispatch | No | No | No | Yes |
Assigned TAM, rapid path to answers | No | No | No | Yes |
Monthly Health Check | No | No | No | Yes |
Twice Annual capacity and performance review | No | No | No | Yes |
[/restab]
[restab title=”Documents”]
[/restab][/restabs]
[restabs alignment=”osc-tabs-left” responsive=”false” tabheadcolor=”#dd3333″]
[restab title=”NST6000MC” active=”active”]
NST6000 Metro Cluster Configuration Systems | |
NST6000-MC storage systems all contain Dual controllers. Includes core operating system, Data Protection Package and E-Centre management platform software licenses. Requires the addition of Storage Connectivity Option(s) from below. | |
NST6330-MC Unified Storage | Part Number |
NST6330 Metro Cluster Storage System, two four-core Intel Xeon processors, 48GB RAM and two GigE ports per controller – Dual Controllers – (120V or 230V). Supports up to 4 storage head units. | NST6330MC-DC |
NST6530-MC Unified Storage | |
NST6530 Metro Cluster Storage System, two six-core Intel Xeon processors, 96GB RAM and two GigE ports per controller – Dual Controllers – (120V or 230V). Supports up to 6 storage head units. | NST6530MC-DC |
NST6730-MC Unified Storage | |
NST6730 Metro Cluster Storage System, two eight-core Intel Xeon processors, 192GB RAM and two GigE ports per controller – Dual Controllers – (120V or 230V). Supports up to 8 storage head units. | NST6730MC-DC |
Storage Connectivity | Part Number |
NST6330-MC Storage Connectivity Option (Must Select One or Two) | |
Fibre Channel Dual-Port Connectivity Pack – Adds two dual-port 8Gb/s FC ports per controller for connection to a synchronously replicated pair of FC-connected E18, E48 or E60 storage unit (plus expansion unit). Includes license to use. | NST6K-FC8-DPMCP |
NST6530-MC Storage Connectivity Option (Must Select One or Two, Maximum One Quad-Port Pack) | |
Fibre Channel Dual-Port Connectivity Pack – Adds two dual-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48 or E60 storage unit (plus expansion unit). Includes license to use. | NST6K-FC8-DPMCP |
Fibre Channel Quad-Port Connectivity Pack– Adds two quad-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48, or E60 storage units (plus expansion units) and license to use. | NST6K-FC8-QPMCP |
NST6730-MC Storage Connectivity Option (Must Select One or Two) | |
Fibre Channel Dual-Port Connectivity Pack – Adds two dual-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48 or E60 storage unit (plus expansion unit). Includes license to use. | NST6K-FC8-DPMCP |
Fibre Channel Quad-Port Connectivity Pack– Adds two quad-port 8Gb/s FC cards per controller for connection to a synchronously replicated pair of FC-connected E18, E48, or E60 storage units (plus expansion units) and license to use. | NST6K-FC8-QPMCP |
SFP+ Single Mode Transceiver 8Gb/10km – (Must select quantity 1 for each FC port on both E-Series and NST) | NST6K-8GS-SMT |
Host Connectivity (Select Up to One) | |
Pair of Dual RJ-45 port 10GBASE-T IO module, based on Intel® Ethernet Controller X540 | NST6K-10GR-DPCP |
Pair of Dual SFP+ port 10GbE IO module based on Intel® 82599 10 Gigabit Ethernet Controller | NST6K-10GS-DPCP |
Host Connectivity (Select Maximum Two) | |
Pair of 10GbE NIC with dual RJ-45 interfaces, includes license to use | NST-10GR-DPCP |
Pair of 10GbE NIC with dual SFP+ SR interfaces, includes license to use | NST-10GS-DPCP |
Pair of 1GigE, Dual-port NIC, RJ-45 interfaces, includes license to use | NST-1GR-DPCP |
Pair of 1GigE, Quad-port NIC, RJ-45 interfaces, includes license to use | NST-1GR-QPCP |
FASTier Performance Boost (Optional) – Use NST6000 FASTier TAB and select accordingly for NST6000-MC model | |
Performance Packs | |
NST6300MC | Part Number |
Performance Pack for NST6300MC. Increases controller RAM from 48GB to 96GB. | NST6300-PP1 |
NST6500MC | |
Performance Pack for NST6500MC. Increases controller RAM from 96GB to 192GB. | NST6500-PP1 |
Storage Units | |
Fibre Channel-connect E-Series | Part Number |
See NST Storage Unites tab to configure storage | |
NST6000 Hardware & Software Support | Part Number |
**All components must be under the same support level** | |
Basic Support – Annual Advance Shipped by NBD, Self Install FRU, Pricing per Metro-Cluster | |
Basic Support, Annual – Tier 1 License (16TB) | OSB-NST6K-16T |
Basic Support, Annual – Tier 2 License (16TB – 64TB) | OSB-NST6K-64T |
Basic Support, Annual – Tier 3 License (64TB – 128TB) | OSB-NST6K-128T |
Basic Support, Annual – Tier 4 License (128TB – 256TB) | OSB-NST6K-256T |
Basic Support, Annual – Tier 5 License (256TB – 512TB) | OSB-NST6K-512T |
Basic Support, Annual – Tier 6 License (512TB – 1024TB) | OSB-NST6K-1P |
Basic Support, Annual – Tier 7 License (1024TB – 2048TB) | OSB-NST6K-2P |
Basic Support, Annual – Tier 8 License (2048TB – 4096TB) | OSB-NST6K-4P |
Basic Support, Annual – Tier 9 License (4096TB – 8192TB) | OSB-NST6K-8P |
Enterprise Support – On-Site NBD, Pricing per System per Site | |
Enterprise Support, Annual – Tier 1 License (16TB) | OSE-NST6K-16T |
Enterprise Support, Annual – Tier 2 License (16TB – 64TB) | OSE-NST6K-64T |
Enterprise Support, Annual – Tier 3 License (64TB – 128TB) | OSE-NST6K-128T |
Enterprise Support, Annual – Tier 4 License (128TB – 256TB) | OSE-NST6K-256T |
Enterprise Support, Annual – Tier 5 License (256TB – 512TB) | OSE-NST6K-512T |
Enterprise Support, Annual – Tier 6 License (512TB – 1024TB) | OSE-NST6K-1P |
Enterprise Support, Annual – Tier 7 License (1024TB – 2048TB) | OSE-NST6K-2P |
Enterprise Support, Annual – Tier 8 License (2048TB – 4096TB) | OSE-NST6K-4P |
Enterprise Support, Annual – Tier 9 License (4096TB – 8192TB) | OSE-NST6K-8P |
NST6000 Hardware & Software Support | |
**All components must be under the same support level** | |
Premium Support – 4-Hour Response, Select GEO, Pricing per Metro-Cluster | |
Premium Support, Annual – Tier 1 License (16TB)* | OSP-NST6K-16T |
Premium Support, Annual – Tier 2 License (16TB – 64TB)* | OSP-NST6K-64T |
Premium Support, Annual – Tier 3 License (64TB – 128TB)* | OSP-NST6K-128T |
Premium Support, Annual – Tier 4 License (128TB – 256TB)* | OSP-NST6K-256T |
Premium Support, Annual – Tier 5 License (256TB – 512TB)* | OSP-NST6K-512T |
Premium Support, Annual – Tier 6 License (512TB – 1024TB)* | OSP-NST6K-1P |
Premium Support, Annual – Tier 7 License (1024TB – 2048TB)* | OSP-NST6K-2P |
Premium Support, Annual – Tier 8 License (2048TB – 4096TB)* | OSP-NST6K-4P |
Premium Support, Annual – Tier 9 License (4096TB – 8192TB)* | OSP-NST6K-8P |
Concierge Support – 4-Hour Response, Managed Services, Select GEO, Pricing per Metro-Cluster | |
Concierge Support, Annual – Tier 1 License (16TB)* | OSC-NST6K-16T |
Concierge Support, Annual – Tier 2 License (16TB – 64TB)* | OSC-NST6K-64T |
Concierge Support, Annual – Tier 3 License (64TB – 128TB)* | OSC-NST6K-128T |
Concierge Support, Annual – Tier 4 License (128TB – 256TB)* | OSC-NST6K-256T |
Concierge Support, Annual – Tier 5 License (256TB – 512TB)* | OSC-NST6K-512T |
Concierge Support, Annual – Tier 6 License (512TB – 1024TB)* | OSC-NST6K-1P |
Concierge Support, Annual – Tier 7 License (1024TB – 2048TB)* | OSC-NST6K-2P |
Concierge Support, Annual – Tier 8 License (2048TB – 4096TB)* | OSC-NST6K-4P |
Concierge Support, Annual – Tier 9 License (4096TB – 8192TB)* | OSC-NST6K-8P |
On-Site Installation | |
On-Site installation (per site) based on 1 day includes Travel applies to CONUS and W. Europe all other locations call. | OSI-NST6K-STD |
On-Site installation (per site) – Complex, based on Statement of Work. | OSI-NST6K-PROF |
[/restab]
[restab title=”NST Storage Units”]
NST Storage Units | |
Storage Unit option for FC or SAS for all NST5300s and NST5500s and FC only for all NST6000MCs and SAS only for the NST6530. | |
Existing customers with Legacy E-Series see Legacy Expansion Units tab to order expansion units. | |
Fibre Channel-connected 6Gb/s E-Series Storage Units | Part Number |
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 (max 9 chassis with expansions), maximum 4 head units can be added to NST6330MC, maximum 6 for NST6530MC, and maximum 8 for NST6730MC. | |
E18V with 8.1TB capacity– 450GB SAS Disk / 15000 RPM | E18VHNJ8P1/450 |
E18V with 10.8TB capacity – 600GB SAS Disk / 15000 RPM | E18VHNJ10P8/600 |
E18V with 36TB capacity – 2TB Disks / 7200 RPM | E18VHNJ36N/2 |
E18V with 54TB capacity – 3TB Disks / 7200 RPM | E18VHNJ54N/3 |
E18V with 72TB capacity – 4TB Disks / 7200 RPM | E18VHNJ72N/4 |
E48VT with 21.6TB capacity – 450GB Disks / 15000 RPM | E48VTNJ21P6/450 |
E48VT with 28.8TB capacity – 600GB Disks / 15000 RPM | E48VTNJ28P8/600 |
E48VT with 43.2TB capacity – 900GB Disks / 10000 RPM | E48VTNJ43J2/900 |
E48VT with 96TB capacity – 2TB Disks / 7200 RPM | E48VTNJ96N/2 |
E48VT with 144TB capacity – 3TB Disks / 7200 RPM | E48VTNJ144N/3 |
E48VT with 192TB capacity – 4TB Disks / 7200 RPM | E48VTNJ192N/4 |
E60VT with 27TB capacity – 450GB Disks / 15000 RPM | E60VTNJ27P0/450 |
E60VT with 36TB capacity – 600GB Disks / 15000 RPM | E60VTNJ36P0/600 |
E60VT with 120TB capacity – 2TB Disks / 7200 RPM | E60VTNJ120N/2 |
E60VT with 180TB capacity – 3TB Disks / 7200 RPM | E60VTNJ180N/3 |
E60VT with 240TB capacity – 4TB Disks / 7200 RPM | E60VTNJ240N/4 |
NOTE: For each E60, E48 or E18 selected, please add four (4) LC-LC cables from below. (Does not apply to E60X, E48X or E18X expansion units.) | |
NOTE: Metro Cluster units use single mode fibre provided by the customer. | |
Cables | Part Number |
Fiber Optic LC-LC cable, 3 Meters | CBL-007-3.0M |
Fiber Optic LC-LC cable, 5 Meters | CBL-007-5.0M |
SAS-connected 6Gb/s E-Series Storage Units | |
Maximum 2 storage units can be added to NST5300, maximum 3 for NST5500 and NST6530 (non-MC). | Part Number |
E18V with 8.1TB capacity– 450GB SAS Disk / 15000 RPM | E18VHNS8P1/450 |
E18V with 10.8TB capacity – 600GB SAS Disk / 15000 RPM | E18VHNS10P8/600 |
E18V with 36TB capacity – 2TB Disks / 7200 RPM | E18VHNS36N/2 |
E18V with 54TB capacity – 3TB Disks / 7200 RPM | E18VHNS54N/3 |
E18V with 72TB capacity – 4TB Disks / 7200 RPM | E18VHNS72N/4 |
E48VT with 21.6TB capacity – 450GB SAS Disks / 15000 RPM | E48VTNS21P6/450 |
E48VT with 28.8TB capacity – 600GB SAS Disks / 15000 RPM | E48VTNS28P8/600 |
E48VT with 43.2TB capacity – 900GB Disks / 10000 RPM | E48VTNS43J2/900 |
SAS-connected 6Gb/s E-Series Storage Units | |
Maximum 2 storage units can be added to NST5300, maximum 3 for NST5500 and NST6530 (non-MC). | Part Number |
E48VT with 96TB capacity – 2TB Disks / 7200 RPM | E48VTNS96N/2 |
E48VT with 144TB capacity – 3TB Disks / 7200 RPM | E48VTNS144N/3 |
E48VT with 192TB capacity – 4TB Disks / 7200 RPM | E48VTNS192N/4 |
E60VT with 27TB capacity – 450GB SAS Disks / 15000 RPM | E60VTNS27P0/450 |
E60VT with 36TB capacity – 600GB SAS Disks / 15000 RPM | E60VTNS36P0/600 |
E60VT with 120TB capacity – 2TB Disks / 7200 RPM | E60VTNS120N/2 |
E60VT with 180TB capacity – 3TB Disks / 7200 RPM | E60VTNS180N/3 |
E60VT with 240TB capacity – 4TB Disks / 7200 RPM | E60VTNS240N/4 |
NST Storage Units | |
E-Series V Expansion Units | Part Number |
Maximum 2 expansion units per 6Gb/s E-Series head unit (expansion units must be the same as head units). | |
E18V Expansion Unit with 8.1TB capacity – 450GB SAS Disk / 15000 RPM | E18XVN8P1/450 |
E18V Expansion Unit with 10.8TB capacity – 600GB SAS Disk / 15000 RPM | E18XVN10P8/600 |
E18V Expansion Unit with 36TB capacity – 2TB Disk / 7200 RPM | E18XVN36N/2 |
E18V Expansion Unit with 54TB capacity – 3TB Disk / 7200 RPM | E18XVN54N/3 |
E18V Expansion Unit with 72TB capacity – 4TB Disk / 7200 RPM | E18XVN72N/4 |
E48VT Expansion Unit with 21.6TB capacity– 450GB SAS Disk / 15000 RPM | E48XVN21P6/450 |
E48VT Expansion Unit with 28.8TB capacity – 600GB SAS Disk / 15000 RPM | E48XVN28P8/600 |
E48VT Expansion Unit with 43.2TB capacity – 900GB Disks / 10000 RPM | E48XVN43J2/900 |
E48VT Expansion Unit with 96TB capacity – 2TB Disk / 7200 RPM | E48XVN96N/2 |
E48VT Expansion Unit with 144TB capacity – 3TB Disk / 7200 RPM | E48XVN144N/3 |
E48VT Expansion Unit with 192TB capacity – 4TB Disk / 7200 RPM | E48XVN192N/4 |
E60VT Expansion Unit with 27TB capacity– 450GB SAS Disk / 15000 RPM | E60XVN27P0/450 |
E60VT Expansion Unit with 36TB capacity– 600GB SAS Disk / 15000 RPM | E60XVN36P0/600 |
E60VT Expansion Unit with 120TB capacity – 2TB Disk / 7200 RPM | E60XVN120N/2 |
E60VT Expansion Unit with 180TB capacity – 3TB Disk / 7200 RPM | E60XVN180N/3 |
E60VT Expansion Unit with 240TB capacity – 4TB Disk / 7200 RPM | E60XVN240N/4 |
NOTE: SAS Cables included for all E-Series models | |
SAS-connected Storage Units | Part Number |
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 and NST6530 (max 9 chassis with expansions). Each head unit can have up to 2 additional cascading units. | |
NST224X with 14.4TB capacity – Includes 24x 600GB SAS 10k RPM HDDs and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X14J4/600 |
NST224X with 21.6TB capacity – Includes 24x 900GB SAS 10k RPM HDDs and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X21J6/900 |
NOTE: For each NST224X head unit, please add four (4) SAS CBL-010-xxxxMM cables from below. For each NST224X cascading unit, please add two (2) SAS CBL-010-xxxxMM cables from below | |
SAS-connected Flash Storage Units | |
Maximum 2 head units can be added to NST5300 (max 6 chassis with expansions), maximum 3 for NST5500 and NST6530 (max 9 chassis with expansions). Each head unit can have up to 2 additional cascading units. | |
NST224X All Flash Array with 1.2TB capacity – Includes 6x 200GB eMLC SAS SSD and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X1Q2/200 |
NST224X All Flash Array with 2.4TB capacity – Includes 6x 400GB eMLC SAS SSD and license to use. Can be used as NST224X head unit or cascading from a NST224X | N224X2Q4/400 |
NOTE: For each NST224X head unit, please add four (4) SAS CBL-010-xxxxMM cables from below. For each NST224X cascading unit, please add two (2) SAS CBL-010-xxxxMM cables from below | |
NST224X 1.2TB Disk Pack – Includes 6x 200GB eMLC SAS SSD and license to use. Up to three (3) can be added to N224X1Q2/200 storage array | DP224X1Q2/200 |
NST224X 2.4TB Disk Pack – Includes 6x 400GB eMLC SAS SSD and license to use. Up to three (3) can be added to N224X2Q4/400 storage array | DP224X2Q4/400 |
NST224X Hardware & Software Support | Part Number |
**All components must be under the same support level** | |
MUST select quantity 1 per N224X-1P2/200F and each additional disk pack. MUST select quantity 2 per N224X-2P4/400F and each additional disk packs. | |
Basic Support – Annual Advance Shipped by NBD, Self Install FRU, Pricing per 1.2TB of SSD | |
Basic Support, Annual – Per 1.2 TB | OSB-DP224F-1P2T |
Enterprise Support – On-Site NBD, Pricing per 1.2TB of SSD | |
Enterprise Support, Annual – Per 1.2 TB | OSE-DP224F-1P2T |
Premium and Concierge Support – 4-Hour Response, Select GEO, Pricing per 1.2TB of SSD | |
Premium and Concierge Support, Annual – Per 1.2 TB | OSP-DP224F-1P2T |
Switches | Part Number |
NST5000 SAS Expansion Switch Connectivity Pack for NST5500 and NST6530 only, for connection to 7 storage head units (Includes 2xSAS Switch – 1x1U Mounting Tray) | NST-SASXSW-CP |
NOTE: Add four (4) SAS cables from below | |
Cables | Part Number |
SAS SFF8088 to SFF8088 SAS, 2.0 Meters | CBL-010-2000MM |
SAS SFF8088 to SFF8088 SAS, 3.0 Meters | CBL-010-3000MM |
SAS SFF8088 to SFF8088 SAS, 5.0 Meters | CBL-010-5000MM |
[/restab][/restabs]