| Performance Data | | Tape Speed | | | Read/Write | 79 IPS (2 m/s) | | Search/Rewind | 315 IPS (greater than 8 m/s) | | Tape Load and Initialize to Ready | 18 s | | Search Time | 41 s (average 1st search) | | Maximum Rewind Time | 90 s | | Interfaces (per Drive) | 1 ESCON, 1 Ultra-SCSI or2 Fibre Channel (SC optical) | | Compression | Enhanced LZ-1, 4:1 Ratio | | Individual compression achieved is a function of many variables, including the data characteristics. For example, scientific data usually compresses less than general business data. As a practical guide, mainframe (MVS/ESCON) compression rates are typically 4:1, while client server operating systems (UNIX/NT on SCSI or Fibre) usually achieve in the 2:1 to 2.5:1 range. In all instances, slightly lower or significantly higher numbers may be achieved. | | Data Buffer Size | 8 MB | | Data Transfer Rates | | | Head-to-Tape | 10 MB/s (uncompressed) | | Interface (burst rate) | 100 MB/s Fibre (256 KB) | | Maximum Block Size | 256 kb | | Supported Features | Tape Alert Emulation Modes – Native, 3490E, 3590 FCP-2 (FC Tape) |
|
| Operating Environment | | Temperature | | | Operating | 59° to 90°F (15° to 32°C) Dry Bulb | | Storage | 50° to 104°F (10° to 40°C) | | Shipping | -40° to 140°F (-40° to 60°C) | | Relative Humidity (Non-condensing) | | | Operating | 20% to 80% | | Storage | 10% to 95% | | Shipping | 10% to 95% | | Wet Bulb Maximum | | | Operating | 84°F (29°C) | | Storage | 84°F (29°C) | | Shipping | 84°F (29°C) | | Altitude | | | Operating | 0 to 10,000 ft (0 to 3.05 km) | | Storage | 0 to 10,000 ft (0 to 3.05 km) | | Shipping | 0 to 50,000 ft (0 to 15.24 km) |
|
| Power Source | | Input Voltage | 88 to 264 VAC | | Input Frequencies | 48 to 63 Hz | | Power Consumption | 85 W | | Power Factor | 0.96 minimum |
|
| Cartridge Shell Data | | Form Factor | Half-inch cartridge, 3480/3490E | | Dimensions | 4.92 in. x 4.29 in. x 1.00 in. (125 mm x 109 mm x 25.88 mm) | | Weight | 9.17 oz (0.26 kg) |
|
| Media Data | | Media | Advanced Metal Particle | | Substrate | Polyethylene Naphthalate (PEN) | | Coercivity | 1625+/-75 Oersteds (130 +/16.0 KA/m) | | Number of Tracks | 288 | | Capacity | 60 GB uncompressed | | Archival Life | 15 to 30 yrs | | Durability | | Short-length Durability | 80,000 write/read passes minimum | Long-length Durability | 6,500 write/read passes minimum | | Uncorrected Bit Error Rate (BER) | 10-18 | | Permanent Errors | Zero | | Load/Unloads | 10,000 minimum | | Track-following Servo | Factory pre-recorded Caution: Do not bulk-erase cartridges. |
|
| Operating Environment | | Temperature | | | Operating | 60° to 90°F (16° to 32°C) | Storage (Up to four weeks) | 41° to 90°F (5° to 32°C) | | Storage (Archive) | 65° to 79°F (18° to 26°C) | | Shipping | 40° to 104°F (4° to 40°C) | | Relative Humidity (Non-condensing) | | | Operating | 20% to 80% | Storage (Up to four weeks) | 5% to 80% | Storage (Archive) | 40% to 60% | | Shipping | 5% to 80% | | Wet Bulb Maximum | | | Operating | 79°F (26°C) | Storage (Up to four weeks) | 79°F (26°C) | Storage (Archive) | 79°F (26°C) | | Shipping | 79°F (26°C) |
|